• C90 Series Single Stage Back Pressure Steam Turbine
  • C90 Series Single Stage Back Pressure Steam Turbine
  • C90 Series Single Stage Back Pressure Steam Turbine
  • C90 Series Single Stage Back Pressure Steam Turbine
  • C90 Series Single Stage Back Pressure Steam Turbine
  • C90 Series Single Stage Back Pressure Steam Turbine

C90 Series Single Stage Back Pressure Steam Turbine

After-sales Service: Global Service
Warranty: 18 Months After Shipment Date
Power: 200-3000kw
Generator Type: Alternator
Output Type: AC Three Phase
Certification: CCC, ISO, CE
Customization:
Gold Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
C90
Standard
Standard
Type
Pulse Type
Generator
Synchronous
Motor Type
Asynchronous
Frequency
50Hz
Freq
60Hz
Voltage
380/430
Heat Resource
Waste Heat
Boiler Type
Waste Heat Recovery Boiler
Power Consumption
Energy Saving
Transport Package
Sea Worht
Specification
200-3000KW
Trademark
CHENYANG
Origin
China
HS Code
8406811000
Production Capacity
50 Sets/Year

Product Description

ADVANTAGES OF SMALL SCALE PRESSURE DIFFERENCE COGENERATION SET
- High flexibility,
- Low investment and quick back,
- Effectively solving the industrial waste heat, differential pressure utilisation,
- Reducing costs and increasing efficiency for enterprises, and meeting customer needs.

C90 SERIES SINGLE STAGE BACK PRESSURE STEAM TURBINE
CHARACTERISTICS
- One Curtis wheels 1040mm.
- Electronic governor for speed control, Japanese brand
- Or mechanical governor TG17 or TG13 of Woodward
- Main shaft speed 1500~4500r/min, gear box optional.
- Suitable for low pressure and temperature steam drive.
- Better energy saving and higher efficiency.
TECHNICAL SPECIFICATIONS
Model Rated power (kW) Speed (r/min) Intake pressure (MPa) Intake temperature (ºC) Exhaust pressure (MPa) Steam consumption (t/h)
B0.25-1.0/0.2 250 3000 1.0 305 0.2 18.4
B0.32-0.98/0.55 320 3000 0.98 300 0.55 38.5
B0.5-0.98/0.5 500 3000 0.98 300 0.5 40.06
B0.6-0.8/0.2 600 3000 0.8 250 0.2 21.3
B0.6-0.98/0.3 600 3000 0.98 300 0.3 22.75
B0.63-0.98/0.15 630 3000 0.98 300 0.15 16
B0.7-0.98/0.25 700 3000 0.98 300 0.25 20
B1.0-0.9/0.15 1000 3000 0.9 300 0.15 17
B1.0-0.98/0.2 1000 3000 0.98 300 0.2 17.6
B1.25-1.0/0.2 1250 3000 1.0 330 0.2 17.2
NOTE:
- The intake and exhaust pressure is absolute pressure.
- Steam turbine weight 3.28 tons.

SUCCESSFUL PROJECTS PRESENTATION
USER: A NEW MATERIAL FACTORY WITH STEAM PRESSURE DIFFERENCE FOR PRODUCTION
MODEL: B1.7-0.95/0.5
POWER: 1700KW
INTAKE PRESSURE: 0.95MPa FROM HEAT RESOURCE
EXHAUST PRESSURE: 0.5MPa FOR PRODUCTION
GENERATOR: SYNCHRONOUS GENERATOR

C90 Series Single Stage Back Pressure Steam TurbineC90 Series Single Stage Back Pressure Steam TurbineC90 Series Single Stage Back Pressure Steam TurbineC90 Series Single Stage Back Pressure Steam TurbineC90 Series Single Stage Back Pressure Steam TurbineC90 Series Single Stage Back Pressure Steam Turbine
C80 SINGLE STAGE BACK PRESSURE STEAM TURBINE
- One Curtis wheel, with pitch circle diameter of 800mm.
- Electronic governor for speed control
- Or mechanical governor TG17 or TG13 of Woodward
- Main shaft speed 1500~4500r/min, gear box optional.
- Suitable for low pressure and temperature steam for better energy efficiency.
TECHNICAL SPECIFICATIONS
Model Rated power (kW) Speed (r/min) Intake pressure (MPa) Intake temperature (ºC) Exhaust pressure (MPa) Steam consumption (t/h)
B1-2.35/0.784 1000 3000 2.35 390 0.784 23.36
B1-2.35/0.98 1000 3000 2.35 390 0.98 28.35
B1.6-2.35/0.784 1600 3000 2.35 390 0.784 22.56
B1.6-2.35/0.882 1600 3000 2.35 390 0.882 25.21
B1.6-3.43/0.784 1600 3000 3.43 435 0.784 17.21
B1.6-3.43/0.882 1600 3000 3.43 435 0.882 18.18
B1.6-3.43/0.98 1600 3000 3.43 435 0.98 19.15
B2-3.43/0.784 2000 3000 3.43 435 0.784 16.5
B2-3.43/0.98 2000 3000 3.43 435 0.98 18.85
B2.5-4.0/0.784 2500 3000 4.0 450 0.784 15.86
B2.5-4.0/0.882 2500 3000 4.0 450 0.882 17.48
B0.56-4.9/1.27 560 3000 4.9 480 1.27 37.5


NOTE:
1. Can be customized according to specific reuirements.
2. The intake and exhaust pressure is absolute pressure.

3. Steam turbine weight 3.28 tons.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, CIP, FCA